beautypg.com

Dvs-21, Data sheet, 4ios – Procom 4IOS User Manual

Page 2: Application description

background image

Data Sheet

4IOS


Multifunction I/O Module

The module 4IOS has 4 relay outputs with floating switch contacts, over which
control and remote processes can be triggered as well as loudspeaker circuits
distributed.
The module 4IOS provides interfaces as link between the DVS-21 system and the
outside world. It is able to pass DVS-21 internal statuses as floating signals to the
outside world and non-floating signals from the outside world as floating signals to
the DVS-21 system. For this, eight opto-coupler inputs and four relay outputs can
be used.

The 4IOS module has four independent identical sets.




Application example for the 4IOS with PA and intercom systems


The 4IOS module can be used in various applications and includes the following
functions:

1. In PA systems the function “Distribute Loudspeaker Circuit” [LK-

Aufteilung]
In this function the relay output can be monitored with an opto-
coupler in respect to voice output.

2. In PA and intercom systems the function “Floating Signal or Control

Outputs” [potentialfreie Melde- oder Steuer- Ausgänge]
In the case of transmissions over several systems, the mode of op-
eration, “Secure Transmission” [Gesicherte Übertragung] can be ac-

CPU1 4NSA

SV01

V100

Havarie

V100

V100

4IOS

.

.

.

Remote
Operation /
Control /
Monitoring

LS 1

LS n

LS 2

LS 1

LS n

LS 2

Loudspeaker
Distribution

LK1

LK2 .. 5

WPS-04
WPS-08

DTA-012 030/ 048/ 066/ 084/ 114

2DA

Signal Inputs

Application Description:

Input 1 .. 8

4IOS

4IOS

DVS-21

Date: 13.03.2009

Page:

2/8 Author:

HS

Document-No.:

DB_4IOS_2804_01