DS1846

9 of 16

o

When the supply being monitored decays to the voltage sense point, the DS1846 pulses the

NMI

output

to the active state for a minimum 200 s. The

NMI

power-fail detection circuitry also has built-in

hysteresis of 100 V. The supply must be below the voltage sense point for approximately 5 s before a

low

NMI

will be generated. In this way, power supply noise is removed from the monitoring function,

preventing false interrupts. During a power-up, any detected IN pin levels below V

TP

by the comparator

are disabled from generating an interrupt until V

CC

rises to V

CCTP

. As a result, any potential

NMI

pulse

will not be initiated until V

CC

reaches V

CCTP

.

Connecting

NMI

to

PBRST

would allow the non-maskable interrupt to generate an automatic reset when

an out-of-tolerance condition occurred in a monitored supply. An example is shown in Figure 5.

2- Wire Protocol Data Transfer Protocol Figure 2

2-Wire AC CHARACTERISTICS Figure 3