beautypg.com

Model 577 magnavalve – Electronics 577 User Manual

Page 2

background image

* MODEL 577 MagnaValve *

* MODEL 577 MagnaValve *

56790 Magnetic Drive Mishawaka, In. USA 46545 (574) 256-5001

56790 Magnetic Drive Mishawaka, In. USA 46545 (574) 256-5001

577CDA

T

A

.CDR

06/27/2005

577CDA

T

A

.CDR

06/27/2005

Input : +12Vdc @ 100mA max.

: -12Vdc @ 60mA max.

Display : None
Output : 0 - 5Vdc
Adjustments : Zero, Span
Accuracy : +/- 10% (of full scale)

Input : +50Vdc @ .62A
Output : 0.2 - 2.0 lbs/min
Pressure Range : 100 PSI
Media: Steel shot
Mode: Normally closed
Temp. Range : 32 - 122° F

0 - 50° C

SPECIFICATIONS

SENSOR

VALVE

JUNCTION BOX

SPAN

ZERO

1

2

3

4

5

6

OUT

GND

+12V

-12V

NEG

POS

BLK

BRN

ORG

RED

WIRE LEADS

WIRE LEADS

VD11 Valve Driver

CABLE
BELDEN 9773
OR EQUAL
3 PAIR SHIELDED

MAY SUBSTITUTE
6 CONDUCTOR
PLUS SHIELD 18 AWG

4.90" [124.46

]

4.90" [124.46

]

6.00"

[152.40

]

6.00"

[152.40

]

3.00" [76.20

]

3.00" [76.20

]

3.14" [79.75

]

3.14" [79.75

]

7.30"

[ 185.42 ]

7.30"

[ 185.42 ]

4.50"

[ 114.30 ]

4.50"

[ 114.30 ]

3.50" [88.90

]

3.50" [88.90

]

1“ NPT
BOTH ENDS

1“ NPT
BOTH ENDS

.875“ DIA.
[ 22.225 ]
1/2“ CONDUIT HOLE
ON BOTTOM AND
RIGHT SIDE OF
JUNCTION BOX

.875“ DIA.
[ 22.225 ]
1/2“ CONDUIT HOLE
ON BOTTOM AND
RIGHT SIDE OF
JUNCTION BOX

Note: The MagnaValve is designed to
operate in a vertical position and must
be mounted within 5 degrees of vertical

Note: The MagnaValve is designed to
operate in a vertical position and must
be mounted within 5 degrees of vertical