In case of the 5-channel VDPLP64xx, you will have to set the start address of the first unit to
001 (CH1~4), the second unit to 006 (1 + 5) (CH5~8), the third to 011 (6 + 5) (CH9~12), and
so on.
•
Use the UP- [2] or DOWN-button [3] to select a DMX starting address. After selecting, it takes
±3s before the address becomes active. The display shows alternately the address and “d”.
•
The selected address is automatically stored in memory.
•
While a DMX-signal is received, a LED on the lower right will be on.
•
The unit receives DMX values in a packet of 5 channels and mirrors this data on the DMX output
[6]:
DMX channel
Value Range Function
CH1
000-255
red (Out1 level)
CH2
000-255
green (Out2 level)
CH3
000-255
blue (Out3 level)
CH4
0-100
Dimmer
CH5
0-100
Shutter
d) Display ON/OFF
•
When the display does not detect user inputs for ±25s, it will automatically switch off.
•
To switch it on again, press any button (settings are not affected).
e) Key lock
•
Pressing and holding the MODE-button [1] for more than 3s will lock all buttons ([1], [2] and
[3]). The display shows alternately the current mode and “LOC”.
•
Press and hold the MODE-button [1] again for more than 3s to unlock the buttons.
f) Switch-on status
•
The device always returns to the mode/status it was in when it was switched off. However, all
DMX values are cleared at power-off.
g) DMX signal loss
•
The device will retain the status it was in before signal loss.
8.
Cleaning and maintenance
1. All screws should be tight and free of corrosion.
2. The housing, the lenses, the mounting supports and the installation location (e.g. ceiling,
suspension, trussing) should not be deformed, modified or tampered with e.g. do not drill extra
holes in mounting supports, do not change the location of the connections …
3. Mechanically moving parts must not show any signs of wear and tear.
4. The electric power supply cables must not show any damage. Have a qualified technician
maintain the device.
5. Disconnect the device from the mains prior to maintenance activities.
6. Wipe the device regularly with a moist, lint-free cloth. Do not use alcohol or solvents.
7. There are no user-serviceable parts.
8. Contact your dealer for spare parts if necessary.
9.
Technical specifications
VDPLP64B2
VDPLP64C2
VDPLP64B3
VDPLP64C3
colour
black
chrome
black
chrome
power supply
90-250VAC / 50-60Hz (switching power mode)
power consumption
20W
44W
DMX channels
5
number of LEDs
177 (36 R, 83 G, 58 B)
39 x 1W (9 R, 18 G, 12 B) - Edison
beam angle
20°
dimensions
Ø186 x 252mm
weight
1.5kg
2kg