G3516 – Milton CAT G3516 1800 rpm 1040 kW 60 Hz Spec Sheet User Manual
Page 3
G3516
GAS GENERATOR SET
TECHNICAL DATA
G3516 LE Standby Power Gas Generator Sets — 1800 rpm
Power Rating @ 0.8 PF without Fan
ekW
1040
kV•A
1300
Generator Frame Size
693
Engine Lubricating Oil Capacity
gal
106
System Backpressure (Max Allowable)
in water
27
Exhaust Flange Size — (Internal Diameter)
in
7.1
Length
in
187.9
Width
in
86.8
Height
in
79.2
Shipping Weight
lbs
20 560
Engine Coolant Capacity with Radiator
gal
100% Load
Fuel Consumption (100% load) with Fan
BTU/bhp-hr
7899
per ISO3046/1: +5%, -0% tolerance
Motor Starting (35% voltage dip)
SkVA (volt)
2626 (480)
Combustion Air Inlet Flow Rate
ft
3
/min
3435
Exhaust Gas Flow Rate (at stack temp)
ft
3
/min
8583
Heat Rejection to Aftercooler
BTU/min
9746
Heat Rejection to Exhaust (total)
BTU/min
54 853
Heat Rejection to Jacket Water (total)
BTU/min
58 557
Heat Rejection to Atmosphere from Engine
BTU/min
7155
Heat Rejection to Atmosphere from Generator
BTU/min
2821
Exhaust Gas Stack Temperature
Deg F
1603
Deration for Engine
Altitude – 3.5% per 500 feet above
ft
4000
2% per 10° F above
Deg F
77
* Note: For permitting see TMI data.
- G150LG4 150kW_188kVA Level 2 Attenuated Enclosure Sound Data (1 page)
- G200LG4 200kW_250kVA Input-Output Module (1 page)
- C15 Factory Weather Protected Enclosures (2 pages)
- G230LG4 230kW_288kVA Weather Protective Enclosure Sound Data (1 page)
- 3512C 1500 kW 1875 kVA 60 Hz 1800 rpm 480 Volts Spec Sheet (6 pages)
- G200LG4 200kW_250kVA Open Sound Data (1 page)
- C15 Standby 350 ekW 438 kVA 60 Hz 1800 rpm 480 Volts Performance Data (8 pages)
- D100-6 100kW Spec Sheet (6 pages)
- 3516C HD 2500 kW 3125 kVA 60 Hz 1800 rpm 480 Volts Generator Data (10 pages)
- G200LG4 200kW_250kVA Battery Charger (1 page)
- C15 400 ekW 500 kVA 60 Hz 1800 rpm 480 Volts Spec Sheet (6 pages)
- G100LG4-2 100kW_125kVA Spec Sheet (5 pages)
- C32 1000 kW 1250 kVA 60 Hz 1800 rpm 480 Volts Spec Sheet (6 pages)
- G300LG 300kW_375kVA Alternator_Strip_Heater (2 pages)
- C27 Sub-Base Fuel Tank Base (4 pages)
- C27 800 kW 1000 kVA 60 Hz 1800 rpm 480 Volts Sound Data (4 pages)
- D100-6_S 100 kW Battery Heater (1 page)
- C18 600 kW 750 kVA 60 Hz 1800 rpm 480 Volts Spec Sheet (6 pages)
- G35LG 35 kW Performance Data: LG Propane Gas Properties (4 pages)
- G275LG 275kW_344kVA Level 1 Attenuated Enclosure Sound Data (1 page)
- D100-6S 100 kW Spec Sheet (6 pages)
- G300LG 300kW_375kVA Attenuated Enclosure Sound Data (1 page)
- G200LG4 200kW_250kVA Level 1 Attenuated Enclosure Sound Data (1 page)
- C18 600 kW 750 kVA 60 Hz 1800 rpm 480 Volts Performance Data (8 pages)
- G175 LG4 Spec Sheet (6 pages)
- C18 600 kW 750 kVA 60 Hz 1800 rpm 480 Volts Sound Data (3 pages)
- G300LG 300kW_375kVA Alternator Data (1 page)
- G3412 350 kW Continuous 350 kW 60 Hz Performance and Sound Data (3 pages)
- G175 LG4 Controller Specifications (4 pages)
- C18 Factory Sub-Base Tank (2 pages)
- G100LG4-2 100kW_125kVA Open Sound Data (1 page)
- G35LG 35 kW H-100 Control Panel (2 pages)
- G70LG 70kW_88kVA Spec Sheet (5 pages)
- C15 Standby 350 ekW 438 kVA 60 Hz 1800 rpm 480 Volts Sound Data (3 pages)
- G300LG 300kW_375kVA Weather Protective Enclosure Sound Data (1 page)
- D60-6 60 kW Spec Sheet (6 pages)
- G150LG4 150kW_188kVA Alternator Data (1 page)
- C32 Silencer – optional low profile critical (1 page)
- G250LG4 250kW_313kVA Open Sound Data (1 page)
- C32 1000 kW 1250 kVA 60 Hz 1800 rpm 480 Volts Sound Data (2 pages)
- D100-6_S 100 kW Automatic Voltage Regulator R438 (2 pages)
- G200LG4 200kW_250kVA Weather Protective Enclosure Sound Data (1 page)
- D80-6 80kW Spec Sheet (6 pages)
- G300LG 300kW_375kVA 21 Light Remote Annunciator (2 pages)
- G275LG 275kW_344kVA Spec Sheet (5 pages)