Factory installed standard & optional equipment – Milton CAT 3516C HD 2500 kW 3125 kVA 60 Hz 1800 rpm 480 Volts Spec Sheet User Manual
Page 2
®
STANDBY 2000 ekW 2500 kVA
60 Hz 1800 rpm 480 Volts
FACTORY INSTALLED STANDARD & OPTIONAL EQUIPMENT
System
Standard
Optional
Air Inlet
• Single element canister type air cleaner
• Service indicator
• Dual element & heavy duty air cleaners (with
pre-cleaners)
• Air inlet adapters & shutoff
Cooling
• Radiator with guard (43°C)
• Coolant drain line with valve
• Fan and belt guards
• Caterpillar Extended Life Coolant
• Low coolant level & high temperature alarm or
shutdown
• Radiator duct flange
• Jacket water heater
Exhaust
• Dry exhaust manifold
• Flanged faced outlets
• Mufflers and Silencers
• Stainless steel exhaust flex fittings
• Elbows, flanges, expanders & Y adapters
Fuel
• Secondary fuel filters
• Fuel priming pump
• Flexible fuel lines
• Fuel cooler*
*Not included with packages without radiators
• Water separator
• Duplex fuel filter
Generator SR4B
• Permanent magnet excited
• Class H insulation
• Class F temperature (105°C prime/130°C standby)
• Winding temperature detectors(select models)
• Anti-condensation space heaters
• Oversize & premium generators
• 2/3 Pitch
Power Termination
• Bus bar (NEMA and IEC meachanicallug holes)
-right side standard
• Top and bottom cable entry
• Circuit breakers, UL listed, 3 pole with shunt trip, 80%
or 100% rated, choice of trip units, manual or
electrically operated (low voltage only)
• Circuit breakers, IEC compliant, 3 or 4 pole with shunt
trip (low voltage only), choice of trip units, manual or
electrically operated
• Shroud cover for bottom cable entry
• Power terminations can be located on the left and/or
rear as an option. Also, multiple circuit breakers can
be ordered (up to 3)
Governor
• ADEM™ 3
• Load share module
Control Panels
• User Interface panel (UIP) - rear mount (standard)
• EMCP3.1 Genset Controller
• Speed adjust (on panel)
• AC&DC customer wiring area (right side)
• CAT digital voltage regulator (CDVR) with KVAR/PF
control, 3-phase sensing
• Emergency Stop Pushbutton
• EMCP 3.3
• Option for right or left mount UIP
• Local & remote annunciator modules
• Load share module
• Discrete I/O module
• Generator temperature monitoring & protection
• Voltage Adjust (on panel)
Lube
• Lubricating oil and filter
• Oil drain line with valves
• Fumes disposal
• Gear type lube oil pump
• Oil level regulator
• Deep sump oil pan
• Electric & air prelube pumps
• Manual prelube with sump pump
• Duplex oil filter
Mounting
• Structual steel tube
• Anti-vibration mounts (shipped loose)
• Isolator removal
Spring-type isolator, zone 4
Starting/Charging
• 24 volt starting motor(s)
• Batteries with rack and cables
• Battery disconnect switch
• Battery chargers (10&20AMP)
•45 amp charging alternator
• Oversize batteries
• Ether starting aid
• Heavy duty starting motors
• Barring device (manual)
• Air starting motor with control & silencer
General
• Right-hand service
• Paint - Caterpillar Yellow except rails and radiators
are gloss black
• SAE standard rotation
• Flywheel and flywheel housing - SAE No. 00
• CSA certification
• EU Certificate of Conformance
Note
Standard and optional equipment may vary for UL
2200 Listed Packages. UL 2200 Listed packages may
have oversized generators with a different
temperature rise and motor starting characteristics.
1 May 2006