beautypg.com

VEGA VEGAFLEX 81 Modbus and Levelmaster protocol Coax probe User Manual

Page 71

background image

71

11 Supplement

VEGAFLEX 81 • Modbus and Levelmaster protocol

42283-EN-130314

1

2

0°C

(32°F)

-40°C

(-104°F)

55°C

(131°F)

80°C

(176°F)

200°C

(392°F)

150°C

(302°F)

3

4

-20°C

(-68°F)

Fig. 35: Ambient temperature - process temperature, version with temperature adapter
1 Ambient temperature

2 Process temperature (depending on the seal material)

3 Maximum permissible temperature - standard

4 Limited temperature range - plastic housing and stainless steel housing, electropolished

1

2

0°C

(32°F)

-40°C

(-104°F)

65°C

(149°F)

80°C

(176°F)

150°C

(302°F)

130°C

(266°F)

3

4

-60°C

(-140°F)

Fig. 36: Ambient temperature - process temperature, elastomer-free version for ammonia applications
1 Ambient temperature

2 Process temperature (depending on the seal material)

3 Maximum permissible temperature - standard

4 Limited temperature range - plastic housing and stainless steel housing, electropolished

Viscosity - dynamic

0.1 … 500 mPa s (requirement: with density 1)

Vibration resistance

Ʋ Instrument housing

4 g at 5 … 200 Hz according to EN 60068-2-6 (vibration

with resonance)

Ʋ Coax probe

1 g with 5 … 200 Hz according EN 60068-2-6 (vibration

at resonance) with tube length 50 cm (19.69 in)

Shock resistance

Ʋ Instrument housing

100 g, 6 ms according to EN 60068-2-27 (mechanical

shock)

Ʋ Coax probe

25 g, 6 ms according to EN 60068-2-27 (mechanical

shock) with tube length 50 cm (19.69 in)