– 17 –
AE01000
APPLICATION RANGE
AC
DC
Power factor
1
0.8–0.95
0.4–0.75
(Efficiency 0.85)
EF3000iSE
–2,800W
–2,240W
–950W
EF3000iSEB
Rated voltage
12V
Rated current
12A
NOTE:
9 “–” means below.
9 Application wattage indicates when each device is
used by itself.
9 The simultaneous usage of AC and DC power is
possible but total wattage should not exceed the
rated output.
EX:
9 The overload indicator light 1 comes on when
total wattage exceeds the application range. (See
page 19 for more details.)
c
C
Be sure the total load is within generator rated output otherwise generator damage
will occur.
NOTE:
Some precision equipment is voltage sensitive and may require a more uniform voltage
supply than portable generators provide. Examples include some medical equipment,
personal computers, and some inverters that sense peak and RMS voltage values.
Consult the precision-equipment vendor before relying on any portable generator to pro-
vide power to such equipment.
760-026
q
Generator rated output
2,800VA
Frequency
Power factor
1.0
–2,650W
AC
0.8
–2,100W
144W
DC
—
(12V/12A)
7CH-9-10-a 5/18/04 2:22 PM Page 17