beautypg.com

Connection notes, Connection, Extension cord notes – Yamaha EF3000iSE User Manual

Page 12

background image

– 7 –

Ground (earth) Lead
Diameter:

0.12 mm (0.005 in)/ampere

EX;

10 Ampere

→ 1.2 mm (0.05 in)

1

2

1

2

741-104

AE00088

CONNECTION NOTES

9 Avoid connecting the generator to commercial

power outlet.

9 Avoid connecting the generator in parallel with any

other generator.

1 Correct
2 Incorrect

AE00091

CONNECTION

w

Before the generator can be connected to a build-
ing’s electrical system, a licensed electrician must
install an isolation (transfer) switch in the build-
ing’s main fuse box. The switch is the connection
point for generator power and allows selection of
generator or main line power to the building. This
will prevent the generator from charging the main
power line (backfeeding) when the main power sup-
ply has failed or has been turned off for line repair.
Backfeeding can electrocute or injure line mainte-
nance personnel. Also, generator and building
electrical system damage can occur when normal
operating power returns if unit is used without an
isolation switch.

AE00086

EXTENSION CORD NOTES

9 When using an extension cord, its total length

should not exceed

60 meters for cross section of 1.5 mm square
and
100 meters for cross section of 2.5 mm square.

9 This extension cord should be protected by a tough

flexible rubber sheath (IEC 245) or the equivalent
to withstand mechanical stresses.





7CH-9-10-a 5/18/04 2:22 PM Page 7

This manual is related to the following products: