background image

6

DOLBY S NR

DOLBY S NR is developed incorporating the concept of
professional-use DOLBY SR system into the present
DOLBY B/C NR.
It offers the noise reduction effect increased by about
40%, compared to the former DOLBY C NR, and also the
noise level of the low frequency range is reduced to 1/3.
Highly natural sound can be reproduced with the help of
the modulation controller, which regulates 5 NR units — 2
for low level sounds and 3 for high level, one of which is
for low frequency signals.
DOLBY S NR has also high interchangeability. The tapes
recorded with DOLBY S NR can well be reproduced by
the decks which are equipped only with DOLBY B NR,
headphone stereos or car stereos for example.

3

KX-580

3

1

High frequency sound is
too boosted.

2

Flat.

3

High frequency sound is
absent.

PLAY TRIM control adjustment

When the level of high frequencies is too boosted or
absent while playing a tape recorded on another cassette
deck, adjust the high frequency response with the PLAY
TRIM control.

When high frequencies are
absent, boost the high
frequencies.

+

When high frequencies are
too boosted, attenuate the
high frequencies.

PLAY TRIM

PLAY TRIM

20

100

1k

10k 20k Hz

10 dB

NR-OFF

S-NR

C-NR

B-NR

Noise Reduction Responce

0

+

0

100

10 dB

1k

10kHz

+

_

1

3

2

To stop playback:

Press the STOP button.

To fast forward the tape:

Press the

⁄ button.

To fast rewind the tape:

Press the

! button.

To adjust the volume level:

Use the volume control of the amplifier or receiver.

To use headphones for private listening:

Insert the headphones plug into the PHONES jack.

To adjust the headphones level:

Use the PHONES LEVEL control.

DOLBY NR button setting (in step 2)

DOLBY NR (OFF/

ŸB/ŸC/MPX) button

Be sure to set the DOLBY NR (OFF/

ŸB/ŸC/MPX) button

according to the system used for recording. Each time this
button is pressed, Dolby NR switches as follows:

ŸB(MPX off) For a tape recorded with DOLBY B NR

Only the

ŸB indicator lights.

ŸC(MPX off) For a tape recorded with DOLBY C NR

Only the

ŸC indicator lights.

ŸB MPX on

(available only for recording)

ŸC MPX on

(available only for recording)

OFF

For a tape recorded with DOLBY NR OFF
No indicator lights.

only

DOLBY NR (OFF/

ŸS/MPX) button

For a tape recorded with DOLBY S NR, use this button to
select the appropriate setting. Each time this button is
pressed, DOLBY NR switches as follows:

ŸS(MPX off) For a tape recorded with DOLBY S NR

Only the

ŸS indicator lights.

ŸS MPX on

(available only for recording)

OFF

For a tape recorded with DOLBY NR OFF
No indicator lights.

* Dolby noise reduction manufactured under license from

Dolby Laboratories Licensing Corporation.
“DOLBY” and the double-D symbol

Ÿ are trademarks of

Dolby Laboratories Licensing Corporation.

Note: The MPX filter settings are explained on page 10.