Problem
Problem cause
solution
Pilot will not light
Gas valve may be OFF
Turn the gas valve ON
Tank fuel empty
Refill LPG tank
Air in supply system
Purge air from lines
Loose connection
Check all fittings
Pilot will not stay on
Debris around pilot
Clean dirty area
Loose connection
Tighten connection
Thermocouple bad
Replace thermocouple
Gas leak in line
Check connections
Lack of fuel pressure
Fuel tank is near empty
Burner will no light
Pressure is low
Fuel tank is near empty
Control valve not ON
Turn valve to ON
Thermocouple bad
Replace thermocouple
Pilot light assembly bent
or not in correct location
Place pilot in proper position
and retry