Perreaux SILHOUETTE SXD2 User Manual
Page 25
24
Signal to Noise Ratio
A-Weighted: ..................................................................... 113dB
Unweighted:...................................................................... 110dB
Crosstalk
20Hz: ............................................................................... -113dB
1kHz: ............................................................................... -110dB
20kHz: ............................................................................. -108dB
Audio Connections
Digital Inputs ............................................... 1 Coaxial PCM
(BNC)
.............................................................................. 1 USB
(Type B)
Analog Outputs .........................................1 pair unbalanced
(RCA)
Compatible Operating Systems
Windows: ..................................................XP, 2000, 98SE, 98ME
Mac: .............................................................OS 9.1+, OS X 10.0+
Other Connections
IEC AC mains input receptacle
Mains Input Voltage
115V or 230V AC at 50Hz/60Hz
(Set within the SXD2 at time of manufacture)
Internal Mains Fuse Rating
1 x 2SB 500mA slow blow
(NOT user serviceable)
Overall Dimensions
Width........................................................................216mm (8.5”)
Depth........................................................................169mm (6.7”)
Height........................................................................ 58mm (2.3”)
Weight
Gross ..........................................................................2.1kg (4.6lb)
Net............................................................................. 1.5kg (3.3lb)
Digital Input
Specifications
Explained
Sample Frequency Range ................................32kHz to 192kHz
This is the range of digital input sample frequencies the SXD2 is
capable of detecting and processing. The Red Book compact
disc standard is 44.1kHz and the high resolution DVD-A format
is 192kHz.