beautypg.com

English / a-13, General machine troubleshooting, Se, aquaride – Nilfisk-Advance America BRX 700 Series User Manual

Page 13

background image

FORM NO. 56041541 - AquaRide

SE, AquaRide

SE AXP / BRX 700 series - A-13

ENGLISH / A-13

GENERAL MACHINE TROUBLESHOOTING

Problem Possible

Cause

Remedy

Poor water pick-up

Recovery bladder full

Empty recovery bladder

Recovery bladder drain hose leak

Secure drain hose cap or replace

Recovery tank cover gasket leak

Replace gasket / Seat cover properly

Debris caught in vacuum shoes

Clean vacuum shoes

Vacuum hose clogged

Remove debris

Foam

fi lter cover not seated

Seat cover properly

Poor extracting performance

Worn brushes

Rotate or replace brushes

Wrong cleaning chemical

Consult Nilfi sk-Advance

Moving machine too fast

Slow down

Inadequate solution fl ow

Solution tank empty

Fill solution tank

or no solution

Solution lines, valves, fi lter, or spray jets clogged

Flush lines and clean solution fi lter & spray jets

Solution control valve is in closed position

Place control valve handle in open position

Solution solenoid valves

Clean or replace valves

Machine does not run

Emergency stop switch tripped

Reconnect battery connectors

Operator seat safety switch

Check for open circuit and replace

Main system controller

Check for error fault codes

(see service manual)

Tripped 10 Amp circuit breaker

Check for electrical short circuit & reset

No FWD/REV wheel drive

Drive system speed controller

Check for error fault codes

(see service manual)

Tripped 45 Amp circuit breaker

Check for drive motor overload

Emergency stop switch tripped

Reconnect battery connectors

Vacuum shuts off and display

Plugged vacuum hose(s)

Clear debris

shows “FULL” when
recovery bladder is not full

Vacuuming large amounts of water

Slow down or disable auto shut-off feature

at a high travel speed

(see service manual)

Poor Sweeping Performance

Debris Hopper Full

Empty and clean hopper

Brushes

worn

Replace

brushes

Bristles have taken a set

Rotate brushes

No Detergent Flow

Empty detergent cartridge

Fill detergent cartridge

(AXP/EDS models only)

Plugged or kinked detergent fl ow line

Purge system, straighten lines to remove any kinks

Dry seal cap on detergent cartridge not sealed

Reseat dry seal cap

Detergent ratio slider magnet missing

Replace slider

Detergent pump wiring disconnected

Connect or reconnect wiring

or

backwards

revised 3/06