Making rtd measurements, Making thermistor measurements – National Instruments SCXI-1127 User Manual

Page 54

background image

Chapter 2

Using the SCXI-1127/1128

© National Instruments Corporation

2-19

SCXI-1127/1128 User Manual

NI-DAQ, use the

Thermistor_Convert

function. The VI takes the output

voltage of the temperature sensor, the reference voltage, and the precision
resistance and returns the thermistor temperature.

Alternatively, you can use the following formulas:

T(°C) = T

K

– 273.15

where T

K

is the temperature in Kelvin,

where a = 1.295361

× 10

–3

b = 2.343159

× 10

–4

c = 1.018703

× 10

–7

R

T

= resistance of the thermistor in ohms,

where V

TEMPOUT

is the output voltage of the temperature sensor,

where T(°F) and T(°C) are the temperature readings in degrees Fahrenheit
and degrees Celsius, respectively.

Making RTD Measurements

Figure 2-16 shows an RTD (R

1

) connected to channel 12 on the SCXI-1331

terminal block. The RTD is connected in the 4-wire configuration. It is
recommended that you connect RTDs in a 4-wire configuration to
eliminate the effects of lead resistance on the measurement. See the

4-Wire

versus 2-Wire Resistance Measurement

section for more information.

Making Thermistor Measurements

Figure 2-16 shows a thermistor (R

2

) connected to channel 24 on the

SCXI-1331 terminal block. The thermistor is connected in the 2-wire
configuration. You can connect the thermistor in the two, four, or even
1-wire input configurations. The choice is typically dictated by channel
cost and required accuracy. The 4-wire configuration is ideal and provides

T

K

1

a

b

R

T

ln

(

) c

R

T

ln

(

)

3

+

+

[

]

--------------------------------------------------------------

=

R

T

189 000

V

TEMPOUT

2.5

V

TEMPOUT

--------------------------------------

,

=

T

°F

( )

[T(

°C ) ]9

5

-----------------------

32

+

=