Warning – Poulan Pro SM705 User Manual
Page 9
9
Primer Bulb
Start Lever
Starter Handle
5. Pull starter rope handle sharply until en-
gine starts and runs.
6. Allow unit to run for 10--15 seconds, then
fully squeeze the throttle trigger to disen-
gage the starting system.
STARTING A WARM ENGINE
1. Move ON/OFF switch to the ON position.
2. Squeeze and hold the throttle trigger.
Keep throttle trigger fully squeezed until
engine runs smoothly.
3. Pull starter rope sharply while squeezing
throttle trigger until engine runs.
NOTE:
Normally, the warm starting proce-
dure can be used within 5--10 minutes after
the unit is turned OFF. If the unit sits for more
than 10 minutes without being ran, it will be
necessary to start the unit by following the
steps under STARTING A COLD ENGINE or
following the starting instruction steps shown
on the unit.
STARTING A FLOODED ENGINE
Flooded engines can be started by placing
the ON/OFF switch in the ON position. Move
the start lever to the RUN position and fully
squeeze throttle trigger. Pull the starter han-
dle repeatedly while squeezing throttle trigger
until engine starts and runs. This could re-
quire pulling the starter handle many times,
depending on how badly the unit is flooded.
If the unit still doesn’t start, refer to
TROUBLESHOOTING
TABLE
or
call
1-800-554-6723.
OPERATING THE COUPLER
This model is equipped with a coupler which
enables optional attachments to be installed.
The optional attachments are:
MODEL:
Edger
PP1000E
. . . . . . . . . . . . . . . . . . . . .
Cultivator
PP2000T
. . . . . . . . . . . . . . . . . .
Blower
PP3000B
. . . . . . . . . . . . . . . . . . . .
Brushcutter
PP4000C
. . . . . . . . . . . . . . . .
Pruner
PP5000P
. . . . . . . . . . . . . . . . . . . .
WARNING:
Always stop unit and dis-
connect spark plug before removing or instal-
ling attachments.
REMOVING TRIMMER ATTACH-
MENT (OR OTHER OPTIONAL
ATTACHMENTS)
CAUTION:
When removing or installing at-
tachments, place the unit on a flat surface for
stability.
1. Loosen the coupler by turning the knob
counterclockwise.
Coupler
Knob
LOOSEN
TIGHTEN
Upper
Shaft
Lower
Attachment
2. Press and hold the locking/release button.
Locking/Release
Button
Coupler
Upper Shaft
Lower Attachment
3. While securely holding the engine and
upper shaft, pull the attachment straight
out of the coupler.
INSTALLING OPTIONAL ATTACH-
MENTS
1. Remove the shaft cap from the attach-
ment (if present).
2. Position locking/release button of attach-
ment into guide recess of coupler.
3. Push the attachment into the coupler until
the locking/release button snaps into the
primary hole.
4. Before using the unit, tighten the knob se-
curely by turning clockwise.
Coupler
Primary Hole
Upper
Shaft
Locking/
Release
Button
Attachment
Guide Recess