Fuses, Cutting height adjuster, Fuel shut off valve – Poulan Pro 461ZX_966681801 LAWN TRACTOR User Manual
Page 22: Controls
CONTROLS
22
Fuses
Fuses are located on the left hand side of the
machine. They are accessed by tilting the seat
forward. They are flat pin fuses of the same type used
in automobiles.
There are two fuses with ratings and functions:
20 Amp Primary fuse
7.5 Amp Mower deck coupling
Fuel Shut Off Valve
The fuel shut off valve is located at the left rear of the
seat. The valve is off when the handle tab is turned
perpendicular to the fuel line.
8011-419
Fuel shut off valve in the CLOSED position
8011-420
Fuses
Cutting Height Adjuster
To set the desired deck cutting height, press the
release button and move the lever forward to the
correct cutting height on the cutting plate. The cutting
height range is from 1½" (38mm) to 4" (102mm) in ½"
(13mm) increments. The heights are measured from
the ground up to the blade tip with the engine not
running.
8058-019
Mower deck lifting lever
IMPORTANT INFORMATION
To obtain an even cutting height it is important
that the air pressure in all four tires is the
same 15 psi (1 bar).
IMPORTANT INFORMATION
Always use the high position to transport.