beautypg.com

Norman, Advanced operation, Service – Photo Control/Norman ML600 Monolight User Manual

Page 4: Diagnostic troubleshooting / error codes, General troubleshooting, Specifications

background image

7

ADVANCED OPERATION



Alarm System
In the event of a misfire the LED display will blink bFL (see page 7). The alarm system is
reset automatically by flashing the unit or by pressing any button on the control panel.


Thermal Protection
The ML600 is protected with an internal overtemp cutout. In the event of an overtemp, the
modeling light will be disabled.


SERVICE



Should not be attempted by user. Consult an authorized Norman Service Center.

Modeling lamp or flashtube replacement. Always unplug unit and discharge stored energy
by pressing the Test button. Wait 10 minutes for any residual charge on the main capacitors to
bleed off and let the flashtube and modeling lamp cool before handling. Always handle
modeling lamp with clean gloves or cloth to avoid transfer of body oils to lamp dome.
Carefully remove old flashtube and/or modeling lamp and replace with new.

Never place metal object or fingers into modeling lamp or flashtube sockets.


DIAGNOSTIC TROUBLESHOOTING / ERROR CODES



This information can assist the operator in determining the source of a malfunction and it can
assist an authorized Norman service center in servicing a Norman Monolight. These codes
flash on the LED Display, signifying the following:

General Errors

bFL –

Indicates a misfire. Check if flashtube is installed, flashtube may need replacement.

hot –

Indicates internal temperature has exceeded normal operating limits. Modeling lamp

will be disabled and automatically enabled when internal temperature returns to normal
operating range.






8

GENERAL TROUBLESHOOTING



Unit will not flash:

Flashtube is not installed properly. (see page 4)

Sync cord polarity not correct (see ‘SYNC Outlet’ page 6)


Unit does not turn on:

Check power cord

Check circuit breaker


Photo Eye does not flash unit:

Sync cord is plugged in (see page ‘Photo Eye’ page 6)

Trigger flash is out of range


Modeling light will not turn on.

Modeling lamp is not installed properly (see page 4)

Modeling lamp is broken

Modeling lamp is turned off. Check the control panel switches (see page 5)


Note: If you are still experiencing trouble after checking the above general troubleshooting
guideline contact Photo Control Customer Service.


SPECIFICATIONS


Power:

600

W-S

Recycle Time:

2 sec.

Flash Duration:

1/1200 sec. (full)

Power Control:

Full to -5 F-Stops

Modeling Lamp:

250W

Modeling Lamp Control:

Off, Ratio, Full

Trigger:

Built-in Photo-eye, ¼” Sync Jack, Test Button

Supply Voltage:

105-125 VAC, 60Hz, 10A

Consumption:

10A

Voltage Stabilization:

+/- 1%

Overload Protection:

10A Circuit Breaker

Weight:

6.14

Lbs.

Flashtube: Quartz, full envelope
Guide Number:

135 at 10 ft., ISO100, Bare Bulb

Sync Voltage:

6 VDC

norman

Manufactured by

Photo Control Corporation

www.photo-control.com

Email: [email protected]

4800 Quebec Avenue North, Minneapolis, MN 55428

(763) 537-3601 Voice, (763) 537-2852 Fax

(Pub. No. 335-028C)

This manual is related to the following products: