Cont'd, Installation cont’d – Lang Manufacturing LG-72S User Manual
Page 7

6
INSTALLATION CONT’D
PHASING
LG / LGS
All griddles are shipped from the factory set up for a three- phase service. Rearrange the wires in the power supply
terminal block to convert the griddle to single phase. Rephasing the griddle is not chargeable to Lang Manufacturing
Company as warranty. To convert to single phase follow the chart below.
Three Phase
Single Phase
Model
Number
Line 1 Line 2 Line 3
Line1
Line 2
LG-24 1,4 2 3 1,3 2,6
LG-36 1,4 2,5 3,6 1,3,5 2,4,6
LG-48
1,4,7 2,5,8 3,6,9 1,3,5,7 2,4,6,8
LG-60
#1
1,4 2,5 3,6 1,3,5 2,4,6
LG-60 #2
1,4
2
3
1,3
2,6
LG-72
#1
1,4 2,5 3,6 1,3,5 2,4,6
LG-72
#2
1,4 2,5 3,6 1,3,5 2,4,6
PB
All griddles are shipped single phase.