GENERATOR

Type ............................................................................. Synchronous
Rotor Insulation ....................................................................Class F
Stator Insulation ...................................................................Class F
Total Harmonic Distortion .........................................................< 5%
Alternator Output Leads 3-phase ........................................... 4-wire
Bearings .........................................................................Sealed Ball
Coupling .......................................................................Flexible Disc
Load Capacity (Standby Rating) ................................ 20/25/30 kW*

* NOTE: Generator rating and performance in accordance with ISO8528-5, BS5514, SAE J1349,

ISO3046 and DIN 6271 Standards. KW rating is based on LPG fuel and may derate with natural
gas.

Excitation System ....................................................................Direct
Generator Output Voltage/kW - 60 Hz
kW

Amp

CB

Size

120/240V, 1-phase, 1.0 pf

20/25/30

83/104/125 100/125/150

120/208V, 3-phase, 0.8 pf

20/25/30

69/87/104

80/100/125

277/480V, 3-phase, 0.8 pf

20/25/30

30/38/45

35/45/50

Generator Locked Rotor KVA Available @ Voltage Dip of 35%
Single-phase or 208 3-phase:

20kW

25kW

30kW

34 KVA 38 KVA 56 KVA

ENGINE

Make ................................................................................... Generac
Model ..................................................................................... In Line
Cylinders and Arrangement ............................................................ 4
Displacement ....................................................................... 1.6 Liter
Bore ...................................................................................... 3.15 in.
Stroke ................................................................................... 3.13 in.
Compression Ratio .............................................................9.75-to-1
Air Intake System ...............................................Naturally Aspirated
Valve Seats ................................................................... Replaceable
Lifter Type .......................................................................... Hydraulic

Engine Parameters
Rated Synchronous RPM ..............................................60 Hz, 3600
HP at rated:

20kW

25kW

30kW

35 HP

45 HP

48 HP

Exhaust System
Exhaust Flow at Rated Output 60 Hz: 20kW

25kW

30kW

209 cfm 235 cfm 240 cfm

Exhaust Temp. at Rated Output:

910°F

1015°F 1022°F

Combustion Air Requirements (Natural Gas)
Flow at rated power, 60 Hz:

20kW

25kW

30kW

80

cfm 90

cfm 92

cfm

Governor
Type .................................................................................. Electronic
Frequency Regulation ...................................................Isochronous
Steady State Regulation ........................................................± .25%
Adjustments:
Speed ............................................................................ Selectable

‹

‹

Engine Lubrication System
Type of Oil Pump ...................................................................... Gear
Oil Filter .............................................................Full Flow, Cartridge
Crankcase Oil Capacity ....................................................4 U.S. qts.

COOLING SYSTEM

Type ....................................................................................... Closed
Water Pump .................................................................... Belt Driven
Fan Speed ................................................................................ 2450
Fan Diameter ..................................................................17.7 inches
Fan Mode ..............................................................................Pusher
Air Flow (inlet air including alternator and
combustion air) ........................................................... 2490 ft

3

/min.

Coolant Capacity ...........................................................2.0 U.S. gal.
Heat Rejection to Coolant ..........................................117,000 Btu/h
Maximum Operating Air Temp. on Radiator ..............60° C (150° F)
Maximum Ambient Temperature ................................50° C (140° F)

FUEL SYSTEM

Type of Fuel ......................................... Natural Gas, Propane Vapor
Carburetor ...................................................................... Down Draft
Secondary Fuel Regulator .................................................Standard
Fuel Shut-off Solenoid ........................................................Standard
Operating Fuel Pressure ...................... 5 in. - 14 in. Water Column

Fuel Consumption - ft

3

/hr (Natural Gas/LPV)

Exercise

25%

50%

75%

100%

Cycle Load Load Load Load

20kW

56/24 124/49 188/75 250/99 315/125

25kW 56/24 161/64

253/101

345/138

430/175

30kW 56/24 209/82

281/117

360/147

437/185

ELECTRICAL SYSTEM

Battery Charge Alternator ............................................12V, 15 Amp
Static Battery Charger ............................................................2 Amp
Recommended Battery ...................................... Group 26, 525CCA
System Voltage .....................................................................12 Volts

Voltage Regulator
Type .................................................................................. Electronic
Sensing ........................................................................ Single-phase
Regulation ................................................................................± 1%
Features ................................................. V/F Adjustable, Adjustable

Voltage and Gain LED Indicators

Power Adjustment for Ambient Conditions
Temperature Deration:
3% for every 10° C above °C

20kW

25kW

30kW

40 40 25

1.65% for every 10° above °F

104

104

77

Altitude Deration:
1% for every 100 m above m

20kW

25kW

30kW

1220

915

182

3% for every 1000 ft. above ft.

4000

3000

600

Controller .................................................R-200

‹

‹

‹