beautypg.com

Error messages, Restoring the factory set data, Specifications – KORG EA-1mkII User Manual

Page 45: Er.1 er.2 er.9 full

background image

8.Data

○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

8.Data

45

Error messages

Data could not be written.

When writing a song to a different song number,
the maximum number of recordable events was
exceeded. Use the Clear Event operation to erase
unwanted events from the song (p.38).

Protect was turned "on" for the memory into which
you attempted to write data. In Global mode, turn
the Protect setting "oFF" (p.40).

When event-recording on a song, event data
memory has filled up. If you attempt to record ad-
ditional events, the "memory full" message will
appear immediately. Either use Clear Event to de-
lete unwanted events from a song, or record blank
data to clear the memory.

Restoring the factory set

data

The pattern and song data with which the EA-1

mk

II

is shipped

from the factory is referred to as the "preloaded data," and you
can restore this preloaded data back into the memory of the
EA-1

mk

II

.

When you do this, the patterns you created and the songs which
use these patterns will be erased, and replaced by the preloaded
data. If you wish to keep the patterns and songs you created,
you must save the data on a data filer etc. before you load the
preloaded data.

1. While simultaneously pressing the TRANSPOSE key and the

WRITE

key, turn on the power.

2. The display will indicate "PLd," and the Play/Pause key will

blink.

3. To load the factory preloaded data, press the blinking Play/

Pause key.

This will require apporoximately 15 seconds.
To cancel, press the Stop/Cancel key.

When loading is complete, the EA-1

mk

II

will return to its initial

state. After several seconds the display will indicate pattern
number "A01," and the EA-1

mk

II

will be in Pattern mode.

Never turn off the power during the Load process. The
data may be damaged.

Cancel

1

3

Specifications

System:

Analog modeling

Number
of parts:

2 parts

Memory
capacity:

256 patterns, 16 songs

Effects:

Distortion, Tempo Delay, Chorus/Flanger

Sequencer:

Pattern

Maximum 64 steps per part
Motion sequence
One parameter for each part, 64 events

Song

Maximum 256 patterns per song
Maximum approximately 65,500 events for
event recording

Connectors:

PHONES

Stereo phone plug
Nominal level: 21 mW + 21 mW (32 ohms)

OUTPUT (PART1/MIX, PART2)

Phone jacks: mono x 2
Nominal output level: -10 dBu
Output impedance: 1 k-ohms

AUDIO IN (phone jack: mono x 1)

Nominal input level: -10 dBu
Input impedance: 47 k-ohms

MIDI (IN, OUT, THRU)

Power supply:

DC 9 V (AC adapter included)

Power
consumption:

5.5 W

Dimensions:

296 (W) x 220 (D) x 55 (H) mm
(with rubber feet)

Weight:

1.5 kg