beautypg.com

Sierra 5391-02 User Manual

Page 24

background image

T12017-Sentry_LANServer_Users_Manual

Page 24 of 59

FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com

Tel: (408) 262-2299 Fax: (408) 262-2269 Toll_Free: 888-509-1970 email: [email protected]

5.9.3.

Potential Problems with Event Logging

5.9.3.1.

File Problems

Events are written to file on the LANServer’s flash disk. When the events page is
viewed the file is read from the flash disk. Errors could occur with the file. These are
reported on the error screen.

Produced when viewing events page

WEB:#19 Err. Reading event record file.
WEB:#20 Err. Bad file pos.
WEB:#21 Err. Opening event record file.


Produced when storing events

WEB:#31 Err. Cant open %s for append.
WEB:#32 Err. Event write failed.
WEB:#33 Err. Cant open %s for append
WEB:#34 Err. Cant open %s for read.
WEB:#35 Err. Event write failed.


Where %s is equal to ‘events.dat’ or ‘events~.dat’

5.9.3.2.

Space Problems

There is a limited amount of space on the flash disk. Event logging is not permitted
to completely fill the free space – a minimum amount of free space is maintained.

If this threshold (currently set at 100k Bytes) is reached then event file maintenance
is performed. If after the maintenance, the available space is still below the
threshold then event logging is automatically disabled and the LANServer prints a
message to the error screen.

5.9.3.3.

Limited number of event records

The LANServer will only store a maximum (currently 400) event records. If this
threshold is reached then event file maintenance is performed.

5.9.3.4.

Event File Maintenance

This procedure is executed by the LANServer when there is too little space to write
new event records or when the maximum number of event records has been
exceeded.

The procedure is as follows:
If an event record is older than 1 day (current setting) then the record is discarded.
• If after they have been removed then if there are more than 350 records (current

setting) then only the 350 most recent events are retained.

• If there is still too little space or two many records, the events.dat file is removed

and all events are lost. If this happens then this message “WEB:#38 Err No
space for Sentry Logging” Is printed in the error log.

This manual is related to the following products: