Source Technologies, LLC ST9620 Secure MICR Printer User’s Guide
59
Error Message
on Display
Printed
Message
Description
Action
Macro Definition
Error
Macro ID
greater than
32767 limit.
The resource number
in the Load Flash
Resource Command
(&%STL...) was over
the 32767 limit.
Check the Load Flash
Resource Command for
syntax/numbering errors.
Macro Definition
Error
Macro size
exceeds
available
space
Flash resource file size
specified in the Load
Flash Resource
Command is too large
for the available space
remaining in the flash
module.
Format flash memory to
remove all existing
resources or upgrade
flash memory to a larger
module.
MICR Definition
Line Count Error
The number of digits in
the MICR definition
Command is not equal
to four, or there is a
non-hexadecimal
character in the count.
Check your software for
errors in the MICR
definition Command
(SMCP).
MICR Password
Error
Password
Length Error.
Password length is not
equal to eight
characters.
Check the Password
Command in your
software, it must be eight
characters long.
MICR Password
Error
Password
Match Error
Password sent does
not match the current
stored password.
Check the Password
Command in your
software.
Non-
hexadecimal
Value Received
Non-
hexadecimal
value
received.
A command contained
a non-hexadecimal
value in a parameter.
Check the Command
(&%STL, STY) syntax for
errors.
Non Integer
Value Received
Non integer
value
received.
A parameter in a
command was not an
integer.
Check the command
(&%STL, STS, STP)
for
syntax/ numbering errors.
Password Not
Enabled Error
A secure command
was sent without the
password being sent
first
Check the software to
ensure that the password
is sent before any secure
commands.
Purge Audit
Report, Then
Format
An SFF command was
received, but there is
audit data in flash
which should not be
erased
Purge the audit data, then
resend the SFF command