beautypg.com

Ope r at io n s – Woodstock SHOP FOX W1808 User Manual

Page 37

background image

-35-

W1808/W1809/W1810 Cyclone Dust Collectors

O

PE

R

AT

IO

N

S

4. Total your list, as shown in the example in Figure

54, to come up with your overall static pressure loss

number for that line.

Note: Always account for a seasoned filter, so you

don't end up with a system that only works well

when the filter is clean.

Note: When calculating static pressure loss to deter-

mine if multiple lines can be left open at the same

time, only include the main line numbers once.

5. Compare the total static pressure loss for that line

to the closest CFM given in the

Performance Curve

section on the machine specifications for your dust

collector (located toward the front of this manual).

— If the CFM for your static pressure loss is above

the requirement of the machine connected to the

end of that branch line, then dust collection will

most likely be successful. Congratulations! You've

just designed your own dust system. Refer to

Page

37 to start buying the components necessary to

make your system a reality.

— If the CFM for your static pressure loss is below

the requirement of the machine, then that line

will not effectively collect the dust. You must

then modify some of the factors in that line to

reduce the static pressure loss. Some of the ways

to do this include: 1) Installing larger duct, 2)

reducing amount of flexible duct used, 3) increas-

ing machine dust port size, 4) moving machine

closer to dust collector to eliminate duct length,

and 5) reducing 90˚ elbows or replacing them with

45˚ elbows.

���������

��������������������������� ����������������

�����

�����������

��������������������������� ����������������

�����

������������������������

����������������

�����

���������������

���������������

������������������������

�����

������������ ��������������������������������

�����

������������������

���������������

������������������������

�����

��������������������������

�������� �����

Figure 54. Example list for totaling static

pressure loss.