Electrical, Extension cords 220v operation, Electrical specifications – Woodstock SHOP FOX W1808 User Manual
Page 15
-13-
W1808/W1809/W1810 Cyclone Dust Collectors
EL
EC
TR
IC
A
L
ELECTRICAL
DO NOT work on your electrical system
if you are unsure about electrical
codes and wiring! Seek assistance from
a qualified electrician. Ignoring this
warning can cause electrocution, fire,
or machine damage.
We do not recommend using an extension cord; however,
if you have no alternative, use the following guidelines:
• Use a cord rated for Standard Service (S).
• Do not use a cord longer than 50 feet.
• Ensure that the cord has a ground wire and pin.
• Use the gauge size listed below as a minimum.
Extension Cords
220V Operation
The Model W1808/W1809/W1810 is wired for 220V single-
phase operation. Always connect this machine to a dedi-
cated circuit (wire, breaker, plug, receptacle) with a
verified ground, using the recommended circuit size and
plugs/receptacles listed at the bottom of this page.
Never replace a circuit breaker with one of higher
amperage without consulting a qualified electrician to
ensure compliance with wiring codes.
This machine must be grounded! Verify the ground before
connecting this machine to the power source.
If you are unsure about the wiring codes in your area
or you plan to connect your machine to a shared cir-
cuit, you may create a fire or circuit overload hazard—
consult a qualified electrician to reduce this risk.
Model
Operating Voltage Amp Draw Min. Circuit Size
Plug/Receptacle
Extension Cord
W1808
220V
14 Amps
20A
NEMA L6-20
14 Gauge
W1809
220V
22 Amps
30A
NEMA L6-30
10 Gauge
W1810
220V
22.4 Amps
30A
NEMA L6-30
10 Gauge
Figure 2. L6-20 and L6-30 plug and
receptacle.
L6-30 P
L6-30 R
Electrical Specifications
L6-20 P
L6-20 R