8

SPECIFICATIONS

Cartridge Type

Dual-Diaphragm, Externally-Biased Condenser

Polar Pattern

Cardioid, Omnidirectional, Bidirectional

Frequency Response

20 to 20,000 Hz

Output Impedance

50 Ω

Attenuator Switch

15 dB

Low-Frequency Filter Switch

Flat, –6 dB/octave below 115 Hz, or –18 dB/octave below 80 Hz

Power Requirements

11–52 V DC phantom power (IEC 61938)

5.8 mA, maximum

Common Mode Rejection (10 to 100,000 Hz)

>50 dB

Polarity

Positive pressure on diaphragm produces positive voltage on pin 2 with

respect to pin 3

Net Weight

492 g (17.4 oz.)

Connector

Three-pin professional audio (XLR), male, balanced

Cardioid

Omnidirectional

Bidirectional

Sensitivity (open circuit

voltage, @ 1 kHz, typical)

–31 dBV/Pa

(29.8 mV)

–37 dBV/Pa

(14.8 mV)

–36 dBV/Pa

(16.8 mV)

Self Noise (equivalent SPL,

A-weighted, typical)

4 dB SPL-A

6 dB SPL-A

7.5 dB SPL-A

Preamplifier Distortion (at 1

kHz, 94 dB SPL)

<0.001%*

Signal-to-Noise Ratio**

90 dB

88 dB

86.5 dB

Clipping

Level (20 Hz

to 20 kHz, 1%

THD)

2500 Ω

load

9 dBV

1000 Ω

load

6 dBV

Dynamic Range

(@ 1 kHz)

2500 Ω

load

130 dB

134 dB

131 dB

1000 Ω

load

127 dB

131 dB

128 dB

Maximum SPL (1 kHz at

1% THD)*

PAD OFF

PAD ON

PAD OFF

PAD ON

PAD OFF

PAD ON

2500 Ω

load

134 dB SPL

150 dB SPL

140 dB SPL

152 dB SPL

139 dB SPL

151 dB SPL

1000 Ω

load

131 dB SPL

147 dB SPL

137 dB SPL

149 dB SPL

136 dB SPL

148 dB SPL

*THD of microphone preamplifier when applied input signal level is equivalent to cartridge output at specified SPL

**S/N ratio is the difference between 94 dB SPL and equivalent SPL of self noise, A-weighted

† 1 Pa=94 dB SPL