beautypg.com

J-400 series, Warning – Jacuzzi J - 470 User Manual

Page 24

background image

Page 18

J-400 Series

5. add start-up Chemicals

Add the spa water chemicals as recommended by your authorized
Jacuzzi spa dealer. See Section titled “Water Quality Maintenance”
(page 71) for general guidance.

warnInG:

rIsK OF POIsOnInG Or DeaTH.

Never leave chemicals opened and accessible to anyone. Use
chemicals according to the vendors instructions. Always store
chemicals in a safe and/or locked location. Keep away from
and out of reach of children.

!

6. establish a stable sanitizer reading

Establish a stable sanitizer reading between 3.0-4.0 ppm chlorine
or 2.0-4.0 ppm bromine. To ensure healthy water conditions, always
maintain a constant sanitizer reading within the levels recommended
by the Association of Pool and Spa Professionals/USA printed on the
inside cover of this manual. If sanitizer levels cannot be stabilized,
perform the Decontamination Procedures on the following page.

note: The “Decontamination Procedure” should also be used after

the spa has been “Winterized” (sec. 14.7, page 70) or has been sitting
without power for an extended period.

7. set spa To Heat

To warm spa water to a comfortable

temperature, follow these steps:

The LCD display on the control panel

displays the actual temperature of the spa

water. Press either the uP or DOwn button
on the Navigational Quad Keypad to increase or decrease the water

temperature by 1 degree.
The heater will

turn off 1 degree above set temperature and turn on 1

degree below set temperature.

Important Heater Details:

The maximum temperature for which the spa can be set is 104 °F

(40 °C) and the minimum is 80 °F (27 °C).

For North American spas: With a 50 amp service, turn off one

of the jet pumps to operate heater. With a 30 amp service, turn

off both jet pumps to operate heater. With a 60 amp service, the

heater will operate with both jet pumps on.

Setting the thermostat at maximum will not accelerate the heating

process. This will only result in a higher ultimate temperature.

The heater operates until the water reaches

1 degree above the

programmed “set temperature”, then turns off. The heater will

reactivate after the water cools to approximately 1 degree below

the “set temperature.”

UP

DOWN

RIGHT

LEFT

SPLASH

This manual is related to the following products: