9.0 OPERATING INSTRUCTIONS

9.6 OPERATOR SETPOINTS

Setpoints are user−adjustable variables in the controller logic that
can be set using the OPERATOR SETPOINTS screen shown opposite.

The name and value of each of the setpoints listed can be seen on
the screen by moving the list up and down using the arrow buttons.

Setpoints associated with options are described in the OPTIONS
sections.

100

PSI

READY TO START

OPERATOR SETPOINTS−

TARGET PRESSURE

105 psi

STATUS

MAIN MENU

SELECT

FACTORY DEFAULTS

OPERATOR SETPOINTS

DEFAULT

MIN.

MAX.

STEP

UNIT

Target pressure

100

65

145 / 203

1

PSI

Automatic stop pressure

110

Target +1

Target +10

1

PSI

Immediate stop pressure

120

Auto

Auto +10

1

PSI

Blowdown mode

Off

Off

On

Condensate release

5

2

20

1

SEC.

Condensate interval

180

90

270

1

SEC.

% savings compared to

Modulation

Energy Rate

0

0

9999.999

Reset Avg.

--

Reset Date

Service menu

1

1

25535

1

A setpoint’s value can be changed by first highlighting the item
and its value and pressing the SELECT button to highlight just the
value. When the value line is highlighted by itself, the value can
be adjusted using the up and down arrow buttons. The CANCEL
and SET buttons appear at this time. Press the SET button to enter
the new value or press the CANCEL button to return the value of
the setpoint prior to using the arrows. The displayed value will
flash twice to indicated that it has been entered into the setpoint
and the pair of setpoint item and value display lines will again be
highlighted together.

Operator setpoints can be exited by pressing the STATUS or MAIN
MENU buttons. If no buttons are pressed within 30 seconds, the
display will return to the CURRENT STATUS screen.

Target pressure

The compressor will try to operate at this pressure setting. The
target pressure ranges and step sizes for each unit of measure are
listed in the table below.

Unit

Min

Max (1S / 2S)

Step

PSI

65

145 / 203

1

BAR

4.4

10 / 14

0.1

kPa

440

1000 / 1400

10

KGCM2

4.5

10.2 / 14.2

0.1

Note: the max target pressure for N250/300H−2S is 145 PSI, 10 BAR ,
1000 kPa, 10.2 KGCM2.