beautypg.com

Saving and recalling settings – Fluke DDS Function Generator 271 User Manual

Page 32

background image

271
Getting Started Manual

The second screen appears:

VALS=ABS AUTO=YES
STEP=01 ACTIVE
LENGTH=0256
LEVEL=+000


Continue entering the pairs of length and level values in
the table until the last step (08).

This is the final screen in which the length and level have
been keyed in, immediately before the final press of the
ENTER

key:

VALS=ABS AUTO=YES
STEP=08 ACTIVE
LENGTH=0005
LEVEL=+153


The remaining steps (9 to 15 inclusive) are all inactive.
Press ESCAPE to complete this part of the set-up. You
should see a brief display indicating that the instrument is
making some calculations on the new waveform.

When the calculations are complete the display will return
to the main menu, on which you can complete the set-up

by changing the amplitude to 1.0 V peak into 50 Ω and the
frequency to 15.625 kHz (or the period to 64 µs).

To initiate the signal, turn the output on and press the
STAIR

key.

22