How To Check The Carbon Brushes (cont)

4. Gently pry the holder down from the motor hous-

ing.

5. Rotate holder from beneath the motor housing

and lift out.

6. Disconnect the brush shunt wire from the holder.

For convenience, cut the terminal from the shunt

wire and remove brush.

7. To put in a new carbon brush, negotiate the

terminal on the shunt wire by the spring and

brush holder guide. Take care not to damage the

spring. See figure 13.

8. Depress the brush into the guide and connec the

shunt wire to the holder.

9. Depress the brush and insert the holder into the

motor housing.

10. Rotate holder beneath motor housing. Relax

brush against commutator.

11. Align posts on holder with holes in housing.

12. Gently pry the holder into the housing.

13. Reattach screws and washers.

14. Start up the machine, if sparking between either

brush and the commutator occurs, use a brush

seating stone on the commutator to promote full

engagement between the brushes and commuta-

tor.

15. Install the motor cover.