4.2.8.2 SMDOUT1Init

Syntax

error_code SMDOUT1Init(u_int8 PortNr);

Description

This function initializes the SM-DOUT1 Module on port PortNr and sets all

output lines to OFF.

Input

u_int8 PortNr

SM-Port number to initialize

(from 0 to 10)

Output

error_code

SUCCESS

E_BMODE

If the module is unknown

or standard OS-9 error code (refer to the OS-9 Technical

Manual Error Codes Section).

Example

RetVal = SMDOUT1Init(0);