Sample tcp/ip communication programs, Sample tcp receive program – Proxima ASA 7911 User Manual
Page 91

85
Message Format:
BYTE
response (ASCII ‘s’, 73H)
BYTE
seqno (from original command)
BYTE
subchannel (1 to 15, from original com
mand)
Baud Rate Confirmation
Purpose: This message is sent after a Set Baud Rate command is
received by the Serial Adapter. Note that this message is sent at
the old baud rate. The Serial Adapter switches to the new baud
rate immediately after this response is sent.
Message Format:
BYTE
response (ASCII ‘b’, 62H)
BYTE
seqno (from original command)
BYTE
baud rate (02H to 0AH, from original
command)
Station Search Reply
BYTE
response (ASCII ‘a’, 61H)
4 BYTES
Serial number (IP address) of responding
station
RangeLAN2 Parameter Confirmation
BYTE
response (ASCII ‘o’, 6FH)
BYTE
seqno
BYTE
Function number
BYTE
status
0= success
1= error