beautypg.com

New lamp ? 34, How to replace the lamp unit, Replacing lamp unit – Marantz DLPTM VP-12S3/VP-12S3L User Manual

Page 40: Initialize the lamp life, English

background image

ENGLISH

CAUTION:

• Do not touch the lamp and the lamp unit carelessly. It is

extremely hot. Wait at least one hour for the lamp to cool
down before handling.

• Do not loosen any screws except for those mentioned

below.

• The lamp may break if handled improperly.
• Do not use other than a Marantz replacement lamp unit.

How to replace the Lamp Unit

PREPARATION:

When replacing the lamp, turn off the power for the
projector. After the cooling fan stops, disconnect the
power cord and wait for one hour until the lamp is cooled
down completely, then replace the lamp.

1.

Press the

STANDBY

button on the remote controller or

the

POWER

button on the projector to turn the projector

off.

2.

After the cooling fan stops, Unplug the AC power cord.

3.

Wait at the least one hour for the lamp and lamp unit to
cool down.

4.

Read the caution and warning labels on the unit.

PATT.

MENU

V-MUTE

ENTER

PATTERN

STANDBY

POWER ON

Replacing Lamp Unit

Initialize the Lamp Life

The lamp has a lamp life of 2000 hours. The projector is
designed to shut OFF power if the lamp is used beyond this
2000 hours lamp life. In such case, replace the lamp and
reset the lamp life counter as follows.

1.

After the message “Lamp Life 0 Hours” appears, power
to the projector shuts OFF. Promptly replace the lamp
with a new one. (

P.34 “Replacing Lamp Unit”)

2.

Once the lamp has been replaced, press the

POWER

ON

button on the remote control or the

POWER

button

on the projector.

The below message appears on the screen for 120 seconds.

3.

Select “Yes”, using the

1 / 2

buttons.

4.

Press the

ENTER

button. The lamp life indicator is now

initialized.

PATT.

MENU

V-MUTE

ENTER

PATTERN

STANDBY

POWER ON

2.

3.

4.

3.

2.

4.

Yes

No

New Lamp ?

34

Lamp cover

WARNING

THIS COVER IS PROVIDED WITH
INTERLOCK TO REDUCE THE RISK OF
EXCESSIVE ULTRAVIOLET RADIATION.
DO NOT DEFEAT ITS PORPOSE OR
ATTEMPT TO SERVICE WITHOUT
REMOVING COVER COMPLETELY.

MODEL NO. VP-16S1 / U1M

AC 120V 60HZ 2.0A

SERIAL NO.

CAUTION : HIGH PRESSURE LAMP
MAY EXPLODED IF IMPROPERLY HANDLED.
REFER SERVICING TO QUALIFIED SERVICE
PERSONNEL.

ATTENTION : LA LAMPE SOUS
HAUTE PRESSION PEUT SI ELLE, N'EST
PAS MANIPULEE CORRECTEMENT,
CONFIER L'OPERATION A UN
PERSONNEL D'ENTRETIEN QUALIFIE.

CAUTION HOT : UNPLUG
THE POWER CORD AND WAIT
60 MINUTES BEFORE CHARGING
THE LAMP.

ATTENTION CHAUD :
DEBRANCER LE CORD ON
D'ALOMENTION ET ATENDER
60 MINUTES AVANT DE
CHANGER LAMPE.

M

MODEL NO. VP-12S1 / N1S

MADE IN JAPAN

FABRIQUE AU JAPON

AC 120V 60H

Z

2.0W

SERIAL NO.

CAUTION :

HIGH PRESSURE LAMP

MAY EXPLODED IF IMPROPERLY HANDLED.
REFER SERVICING TO QUALIFIED SERVICE
PERSONNEL.

ATTENTION :

LA LAMPE SOUS

HAUTE PRESSION PEUT SI ELLE, N'EST
PAS MANIPULEE CORRECTEMENT,
CONFIER L'OPERATION A UN
PERSONNEL D'ENTRETIEN QUALIFIE.

CAUTION HOT :

UNPLUG

THE POWER CORD AND WAIT
60 MINUTES BEFORE CHARGING
THE LAMP.

ATTENTION CHAUD :

DEBRANCER LE CORD ON
D'ALOMENTION ET ATENDER
60 MINUTES AVANT DE
CHANGER LAMPE.

WARNING

THIS COVER IS PROVIDED WITH
INTERLOCK TO REDUCE THE RISK OF
EXCESSIVE ULTRAVIOLET RADIATION.
DO NOT DEFEAT ITS PORPOSE OR
ATTEMPT TO SERVICE WITHOUT
REMOVING COVER COMPLETELY.

This manual is related to the following products: