ZDWT240PBS

GE Monogram Wine Reserve with Liquid Crystal Privacy Glass

Dimensions and Installation Information

Specification Revised 12/06

120040

34-1/2"-35"

24" Min.

23-3/4"

23-3/4" Min.

25-1/2"

Including

Handle

34-1/4"-

34-3/4"

23-3/4"

1-1/2"

Locate Outlet

9"

Max.

10-1/2"

A

Minimum to Wall

110

°

110

° Door

Swing

21-5/8"

23-5/8"

B

Minimum to Wall

90

°

90

° Door

Swing

10"

Minimum to Wall

4"

Minimum to Wall

Installation Space

The Monogram

®

Wine Reserve may be installed beneath a

countertop or can be used free-standing.
• If installing between frameless cabinets, a 1/2”-wide filler
strip or side panel may be required. The filler strip will act
as a spacer between the door case and adjacent cabinet
and will prevent interference with cabinet door swing. The
width of the opening must include filler panels.
Note: When installed, the door should project forward 1” of
adjacent 24”-deep cabinets.

Location Requirements

All Monogram Refrigeration Modules may be closed in on
the top and sides as long as the front is unobstructed for air
circulation and door swing.
• Do not install these products where the temperatures will
go below 55°F (13°C) or above 90°F (32°C).
• Do not install where they will be subject to direct sunlight,
heat or moisture.
• These products are not designed to be stacked one over
the other.

Side-by-Side Installation

For a complete refreshment center, install a Monogram Wine
Reserve and Beverage Center together.
• Products must operate from separate properly grounded
receptacles.
• Do not install where they will be subject to direct sunlight,
heat or moisture.

Door Swing Clearances

All Monogram Refrigeration Modules are factory set for a
110° door swing. When installed in a corner:
• Allow the minimum door swing clearances shown.
• The minimum clearance shown at 90° will allow full
extension of drawers and shelves.

Dimensions and installation instructions are shown in inches.

Listed by

Underwriters

Laboratories

Electrical

A 120V, 60Hz, 15 or 20 amp power supply is required.
An individual properly grounded branch circuit or circuit
breaker is recommended. Install a properly grounded
3-prong electrical recessed into the back wall as shown.
Electrical must be located on rear wall as shown.

Note: GFCI

(ground fault circuit interrupter) is not recommended.