Adjust the minimum burner setting:

When changing from one gas type to another, the
minimum valve output must also be correct,
considering that in this position the flame must be about
5⁄32” (4 mm) long and must remain lit even when the knob
is turned quickly from the maximum to the minimum
position.
The adjustment is performed with the burner lit, as
follows:

Turn the knob to the minimum position.

Remove the knob.

Turn the adjustment screw to the correct setting

with a screwdriver (Fig.17).

For LP/Propane gas, tighten the adjustment screw completely.

4

Re-test for leaks:

Repeat the steps under ‘Leak-testing the cooktop’.

5

Fill in/affix the gas conversion labels:

After completing the gas conversion, fill in the gas conversion labels (supplied with the

conversion kit).

Affix the adhesive/polyester label near the model/serial rating plate on the underside of

the basepan.

Affix the paper label into the appropriate frame at the front of this manual, under the

duplicate data (model/serial/rating) plate.

Gas rate summary

Fig. 17 Adjusting the minimum burner setting

CG122 models

Nominal

power

Reduced

power

LP/PROPANE

11” W.C.P.

NATURAL GAS

4” W.C.P.

Burners

BTU/hr

BTU/hr

injector

[1/100 mm]

By-pass

[1/100 mm]

injector

[1/100 mm]

By-pass

[1/100 mm]

Semi-rapid

6000

1500

72

34

118

adjustable

Rapid 10000

2000

94

44

155

adjustable

CG244 models

Nominal

power

Reduced

power

LP/PROPANE

11” W.C.P.

NATURAL GAS

4” W.C.P.

Burners

BTU/hr

BTU/hr

injector

[1/100 mm]

By-pass

[1/100 mm]

injector

[1/100 mm]

By-pass

[1/100 mm]

Auxiliary

3500

1000

55

27

90

adjustable

Semi-rapid 6000

1500

72

34

118

adjustable

Triple-ring wok

11500

5200

100

65

165

adjustable